Home > Ibm Error > Ibm Error S222

Ibm Error S222

Contents

S237 - 0C - THE NUMBER OF BLOCKS PROCESSED, WHICH IS DETERMINED BY THE POSITION OF THE TAPE, DOES NOT MATCH THE DCB BLOCK COUNT. GOOD LUCK FIGURING THIS ONE OUT! (SAM ACCESS OF AN ICF VSAM COMPONENT, PERHAPS?) S213 - 24 - DURING AN OPEN, A VOLUME HAD A TYPE OF SPLIT CYLINDER ALLOCATION NOT S005 - 08 - THE RBL TYPE OF READ WAS NOT USED FOR THE 3886. POSSIBLE DOS VOLUME.

S205 - 00 - (00 IS THE ONLY POSSIBLE RETURN CODE ASSOCIATED WITH S205) GETMAIN ERROR. S002 - 78 - ERROR RETURN FROM IGWFMPCR WHEN ATTEMPTING TO GIVE CONTROL TO A ROUTINE TO PROCESS PDSE REQUESTS. S106 - 0D - THE CONTROL PROGRAM FOUND AN INVALID RECORD TYPE IN THE LOAD MODULE. Check for subscript errors, missing DD card, file not opened. http://ibmmainframes.com/about16726.html

Abend S222 U0000

S305 - 1C - ZERO LENGTH WAS NOT SPECIFIED ON A SUBPOOL FREEMAIN. This will prevent a long delay on the restart of SMS. S137 - I/O ERROR IN END OF VOLUME LABEL PROCESSING ON MAGNETIC TAPE. ***IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE*** ***S137 OPERAND FOR MORE SPECIFIC INFORMATION: S306 - 30 - THE USER WAS DENIED ACCESS TO THE PROGRAM BY THE SYSTEM AUTHORIZATION FACILITY.

  1. NOT ENOUGH REAL STORAGE AVAILABLE TO BACK A MINIMUM NUMBER OF VSM CELLS (IN LSQA) DURING LOCAL CELL POOL EXPANSION.
  2. NOTE: DAE dump suppression only suppresses the dumps and will not prevent the symptoms of the problems.
  3. S013 - 7C - AN OPEN MACRO WAS ISSUED FOR AN OPTICAL CHARACTER READER DATASET, BUT THE LRECL PARAMETER IN THE DCB WAS ZERO.
  4. How to list the commands issued earlier?
  5. Is This Answer Correct ? 3 Yes 1 No
    Answer / piyush mani i have faced this abend in case of time limit...
  6. S104 - 1C - LSQA REQUEST FAILED - PAGE TABLE PAGED OUT.
  7. S0F9 - 04 - AN SVRB BEING FREED MAY NOT BELONG TO THE SVRB POOL.
  8. However, by this time the 'end phase 1' log record was written and a SRB was scheduled in RRSbatch job address space.
  9. IF THERE IS NO APPARENT EXPLANATION, CONTACT OPERATIONS BEFORE RESUBMITTING. --POSSIBLE CAUSE-- LINE OR CARD ESTIMATE EXCEEDED JCL ERROR CAUSED MOUNT REQUEST FOR INVALID OR NON-EXISTING VOLUME REQUESTED DEVICES NOT CURRENTLY
  10. S106 - 0F - AN UNCORRECTABLE INPUT/OUTPUT ERROR OCCURRED, THE LOAD MODULE HAD AN ERROR WHICH CAUSED THE CHANNEL PROGRAM TO FAIL, OR A LINKLIST LIBRARY EXPANDED INTO ANOTHER EXTENT SINCE

S013 - 28 - AN OPEN MACRO WAS ISSUED WITH OUTPUT OR OUTIN SPECIFIED, BUT THE DCB DID NOT SPECIFY A MACRF OF EXCP, PUT, OR WRITE. S04C - THE TERMINAL MONITOR PROGRAM (TMP) WAS INVOKED AT ENTRY POINT IKJEFT1A AND THE TMP DETACHED A PROGRAM THAT COMPLETED WITH A NON-ZERO COMPLETION CODE (WHICH IS IN REGISTER 15). S0F8 - 1C - THE SVC ISSUER WAS NOT AUTHORIZED FOR SVC MICROCODE ASSIST. User Abends In Mainframe S102 - 0C - INVALID ECB FOR BRANCH ENTRY XMPOST.

S013 - CC - SETPRT PROCESSING FAILED TO SET UP THE DEVICE DURING AN OPEN FOR THE IBM 3800 PRINTING SUBSYSTEM. S104 - 20 - AUTHORIZED PRIVATE REQUEST FAILED - PAGE TABLE PAGED OUT. S002 - RECORD IS GREATER THAN 32,768 BYTES, EXCEEDS MAXIMUM TRACK LENGTH OR STATED BLOCKSIZE, COULD NOT BE CONTAINED IN ONE EXTENT, OR TOO MANY TRACKS SPECIFIED FOR CYLINDER OVERFLOW. ***IF http://www.ibmmainframeforum.com/abends-sql-codes/abend-s222-t9552.html S113 - 38 - AN OPEN WAS ISSUED FOR A VSAM DATA SET WITH A DCB, BUT THE VTOC DOES NOT INDICATE THAT IT IS A VSAM DATA SET.

S002 - 28 - THE ERROR OCCURRED DURING THE CREATION OF A DIRECT DATASET. S222 Charge PROCESSING CONTINUES FOR OTHER DCBS OPENED. S0E0 - 2C - THE SEQUENCE NUMBER IN THE ASTE THAT THE ACCESS LIST ENTRY REFERS TO IS NOT EQUAL TO THE NUMBER IN THE ACCESS LIST ENTRY. RESUBMIT THE JOB.

How To Resolve S322 Abend In Jcl

If we are using select statement, sql error code 100 represents record not found If we are using cursor , in that situation, sql error code 100 represents end of records http://www.ibm.com/support/docview.wss?uid=swg1PK93851 We use this code whenever we open the file, if status code is 00 or 97 we will proceed with our logic, other wise, call error routine. Abend S222 U0000 EITHER A HARDWARE ERROR OCCURRED OR A PROGRAM RUNNING IN KEY ZERO CAUSED DATA DAMAGE. S522 Abend Because of the cancels within a SMS task, i.e.

S013 - 0C - A BUFFER LENGTH OF 0 WAS SPECIFIED FOR A BDAM DATASET FOR WHICH DYNAMIC BUFFERING WAS REQUESTED. S013 - BC - A SYSIN OR SYSOUT DCB WAS OPENED WITH INVALID OPTIONS. S0E0 - AN INVALID OR UNRECOGNIZED PROGRAM INTERRRUPT OCCURRED. --POSSIBLE CAUSE-- THIS LEVEL OF MVS IS NOT THE CORRECT ONE FOR THE HARDWARE, ESPECIALLY IF THE INTERRUPT CODE IS UNKNOWN. ***IF S178 - 1C - LSQA REQUEST FAILED - PAGE TABLE PAGED OUT. Unsuccessful Sort 222

S233 - 38 - THE CALLER SPECIFIED THE 4K SQA BUFFER (BUFFER=YES) BUT AN SVC DUMP WAS ALREADY IN PROGRESS. TOO MANY TRACKS WERE SPECIFIED FOR CYLINDER OVERFLOW. LARGER THAN TARGET FIELD MAX - TRIED TO READ OR WRITE A FILE WHICH WAS NOT OPEN - USED DD DUMMY AND LOGIC SAYS AT END MOVE HIGH VALUES TO FD These jobs are members in PDS.

S052 - A PROGRAM MADE AN INVALID PC/AUTH REQUEST. Mainframe Abend Codes S214 - 10 - THE NUMBER OF BLOCKS PROCESSED ACCORDING TO THE TAPE POSITION DOES NOT MATCH THE DCB BLOCK COUNT. S0E2 - THE ERROR OCCURRED WHILE PROCESSING THE FIRST EXCP OF A VIO DATASET.

S233 - 14 - THE USER-SUPPLIED DATA (FOR HDR= OR HDRAD=) IS GREATER THAN 100 CHARACTERS.

if it possible how to submit ofter the modification. 3 Answers IBM, L&T, What is the purpose of the PARM keyword in the EXEC statement? 3 Answers If we THE DCB IS DUMPED TO THE GTF DATA SET. S20A - 00 - (00 IS THE ONLY POSSIBLE RETURN CODE ASSOCIATED WITH S20A) GETMAIN ERROR. Ief450i S10A - GETMAIN ERROR.

How to compare a dataset with other dataset while viewing or editing it How to find datasets last referenced by you? S013 - C8 - THE OPEN SUBSYSTEM EXECUTOR MODULE WAS PASSED AN ERROR RETURN CODE IN REGISTER 15 AFTER ISSUING THE IEFSSREQ MACRO TO CONNECT THE USER'S ACB TO THE SUBSYSTEM. THIS IS A NO-NO. ANSI LABELS A VALID ONLY FOR 9-TRACK UNITS.

S0C3 - EXECUTION EXCEPTION - THE SUBJECT INSTRUCTION OF EXECUTE IS ANOTHER EXECUTE. --POSSIBLE CAUSE-- UNINTENTIONAL BRANCH, LOSS OF ADDRESSABILITY. S002 - 88 - POINT DETECTED AN ERROR WHILE ATTEMPTING TO RECONNECT TO A PDSE MEMBER FOR I/O. S130 - THE DEQ MACRO SPECIFIED A RESOURCE NOT PREVIOUSLY SPECIFIED BY BY AN ENQ MACRO. S233 - 24 - THE SPECIFIED ASID PARAMETER WAS SYNTACTICALLY INVALID.

S002 - 0C - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OR WRITE OPERATION. CHECK THE JOB LOG LISTING FOR MORE INFO. S002 - 94 - INCORRECT ATTEMPT TO CREATE A PDSE MEMBER SINCE THE MAXIMUM NUMBER OF MEMBERS HAVE ALREADY BEEN CREATED. S004 - 05 - INVALID FORMAT CARD OR AN INVALID DEVICE SPECIFIED WITH OPTICAL MARK READ (OMR).

S16E - 14 - AM VALUE DOES NOT EQUAL DEBAMTYP VALUE. HesabımAramaHaritalarYouTubePlayHaberlerGmailDriveTakvimGoogle+ÇeviriFotoğraflarDaha fazlasıDokümanlarBloggerKişilerHangoutsGoogle'a ait daha da fazla uygulamaOturum açınGizli alanlarGrupları veya mesajları ara RAMESH KRISHNA REDDY ABEND CODES / STATUS CODES JCL | DB2 | CICS | VSAM | IMS ABEND CODE NOT ENOUGH REAL STORAGE AVAILABLE TO BACK A MINIMUM NUMBER OF VSM CELLS (IN LSQA) DURING LOCAL CELL POOL EXPANSION. S013 - 30 - A SEQUENTIAL DATASET USING THE QUEUED ACCESS TECHNIQUE WITH EXCHANGE BUFFERING WAS OPENED FOR OUTPUT, BUT THE BUFFER CONTROL BLOCK ADDRESS (DCBBUFCB) WAS 0.

CORRECT THE LABEL PARAMETER. - OPTCD=Q WAS SPECIFIED BUT IS NOT SUPPORTED BY THE SYSTEM. S112 - 03 - DCB DOES NOT POINT TO A VALID DEB. U0456 - IF PSB IS NOT AVAILABLE (NOT RUNNING/SOMEBODY IS USING) WHAT WE SHOULD DO ? A solution to this problem will be delivered in a future DFSMS release, if there is one, within the next 18 to 24 months.

S013 - A8 - AN INVALID RECORD FORMAT WAS REQUESTED FOR A SYSIN OR SYSOUT DATASET. (RECFM=D, VS, OR VBS ARE INVALID FOR SYSIN) S013 - AC - A QSAM OPEN S002 - 90 - POINT DETECTED AN ERROR WHILE ATTEMPTING TO CONNECT TO A PDSE MEMBER. THE TWO LOW-ORDER BYTES OF REGISTER 15 CONTAIN A HEXADECIMAL REASON CODE. 2101--A VTAM VALIDITY CHECK OF THE USER'S RPL FAILED BECAUSE THE RPL DOES NOT HAVE THE SAM PROTECTION KEY CLOBBERED IOB OR OTHER SVC PARAMETERS - SEE S0C1 S0F3 - MACHINE CHECK INTERRUPTION DISK I/O FAILURE OR MACHINE TROUBLE S0F8 - THE ISSUER OF AN SVC WAS EITHER IN SRB

S002 - 10 - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OPERATION; THE DATASET USES THE TRACK OVERFLOW FEATURE. THIS INSTRUCTION IS NOT VALID IN OS/VS2 (SINCE RELEASE 2). What is db2 plan What is the difference between Cursor stability and Repeatable read.