Home > Ibm Error > Ibm Error S213

Ibm Error S213

Contents

Unable to obtain to obtain enough space to satisfy a REGION= request May need to change REGION statement in the JCL. S029 - AN INVALID VIO REQUEST WAS DETECTED BY THE PAGE OPERATIONS STARTER ROUTINE OF ASM. S0C3 - EXECUTION EXCEPTION - THE SUBJECT INSTRUCTION OF EXECUTE IS ANOTHER EXECUTE. --POSSIBLE CAUSE-- UNINTENTIONAL BRANCH, LOSS OF ADDRESSABILITY. Verify that the correct data set and volume will be accessed.

The SP parameter was specified but the virtual storage area to be released was not within subpool zero. SUGGESTION: Check IMSGen and PSBDump. S013 - 2C - A SEQUENTIAL DATASET USING THE QUEUED ACCESS TECHNIQUE WITH EXCHANGE BUFFERING WAS OPENED FOR INPUT, BUT THE BUFFER CONTROL BLOCK ADDRESS WAS 0. Region size is too small.

Iec143i 213-04

Incorret record format or blocksize; The requested drive is not switched to this machine. For a partitioned dataset, all space was filled when the program attempted to write another record 16 extents had been used when the program attempted to write another record, however no This only works with SYSOUT data sets. 1. S032 - DURING A BISAM OR QISAM OPEN DCBMACRF WAS NOT VALID FOR ISAM.

SA13 The error occurred during execution of an OPEN macro on magnetic tape. See message TCS008I. 1CThe DCB is not valid or is not DSORG=PO. There is invalid data in either control registers 0 or 1, or a segment or page table. Tried to close a file without opening it.

An error was caused by a subsystem interface problem. Iec143i 213-30 S002 - 14 - AN INVALID RECORD WAS ENCOUNTERED ON A PUT OR WRITE OPERATION. DURING THE EXECUTION OF OPEN IT WAS DETECTED THAT THE BLOCKSIZE WAS LARGER THAN THE PRIMARY EXTENT. website here S305 - 10 - LSQA STORAGE IS NOT IN THE SUBPOOL SPECIFIED.

S002 - RECORD IS GREATER THAN 32,768 BYTES, EXCEEDS MAXIMUM TRACK LENGTH OR STATED BLOCKSIZE, COULD NOT BE CONTAINED IN ONE EXTENT, OR TOO MANY TRACKS SPECIFIED FOR CYLINDER OVERFLOW. ***IF S16E - 1C - DEBAMTYP OR DEBTBLOF = 0 FOR TYPE = ADD. S137 - 14 - AN I/O ERROR OCCURRED READING HEADER LABELS FOR A DATASET OPENED FOR INPUT OR INOUT, OR READING THE TRAILER LABEL FOR A DATASET OPENED FOR RDBACK. An I/O error occurred in searching for the module in the library directory. 1.

  • Hex offset 04 contains a copy of the program status word before RTM was entered.
  • Program time out due to looping problem.
  • S028 - A PAGING OPERATION HAS NOT COMPLETED SUCCESSFULLY DUE TO ONE OF THE FOLLOWING: - A PERMANENT I/O ERROR OCCURRED WHILE ATTEMPTING A PAGE-IN OR SWAP-IN OPERATION.
  • SF37 Hardware error.
  • S031 - A QISAM I/O ERROR OCCURRED.

Iec143i 213-30

The data set on DASD output already had 16 extents, but required more space or secondary space was too small or no more space was available on the volume or at ECB specified for PGOUT S171-04 The error was detected by the page services routine. Iec143i 213-04 U0004 GO step of FORTRAN - subrountine fileno - non sequential dataset. S213 Abend In Mainframe S0F0 - AN ERROR OCCURRED WHILE PROCESSING A MACHINE CHECK INTERRUPTION.

S202 - 0C - FOR A WAIT IN A USER KEY, THE ECB ADDRESS IS INVALID. One of the following reason codes are associated with the error: 04An unauthorized caller attempted to free subpool zero. 08An attempt was made to free a subpool number greater than 127. An error occurred while rewinding a tape prior to verifying the volume label. Possible causes: 1. Abend S213 Reason 30

S306 The error occurred during the execution of the LINK, XCTL, ATTACH, or LOAD SERVICE ROUTINES. The record being processed exceeded the allowable size. See message TCS019I. 24An authorized caller attempted to load a module that was not marked as RENT and which was previously loaded by an unauthorized requester. One of the following reason codes are associated with the error: 08The DCB address is invalid. 0CThe DEBCHK VERIFY service failed for the DCB. 46D The attempt to invoke the

S178 - 08 - NOT ENOUGH REAL STORAGE FOR SPACE IN FIXED CSA SUBPOOL. S0C3 An attempt was made to make the EXECUTE machine instruction the target of an EXECUTE instruction, which is not allowed Possible causes & Solution: Not Applicable. The security byte in the header label was not bland and not equal to X'F1'.

SC13-10 An OPEN macro was issued specifying output or extend for a concatenated partitioned dataset, output datasets cannot be concatenated.

The reason code is set to 03. 0C4 A Program Check Interrupt occurred. That function could not be completed. S0CA Decimal overflow exception. S306 - THE ERROR OCCURRED DURING THE EXECUTION OF THE LINK, XCTL, ATTACH, OR LOAD SERVICE ROUTINES.

S102 - 0C - INVALID ECB FOR BRANCH ENTRY XMPOST. S30A - 18 - PRIVATE AREA SUBPOOL NOT FOUND. For variable length records, the blocksize was not four bytes greater than the logical record length. One of the following reason codes are associated with the error: 20An AFX Translation Exception occurred. 21An ASX Translation Exception occurred. 0D6 An invalid PC number was used in a