Ibm X3550 Error Code 9f

Contents

NMI button: Press this button to force a nonmaskable interrupt to the microprocessor. Remove the adapter from the riser card. If a damage is found, replace the system board. (Trained service technician only) If the problem is related to microprocessor socket pins, replace the system board. (Trained Service technician only) Replace Run the Setup utility and select System Information > System Summary > Processor Details to view the microprocessor information to compare the installed microprocessor specifications. (Trained service technician only) Remove and weblink

Now featuring documents to help your research! Follow steps indicated in POST error codes and Integrated management module error messages. See Problem determination tips. 3108007 System configuration restored to default settings Information only. Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error. http://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.ibm.sysx.7944.doc/r_light_path_diagnostics_table.html

Ibm X3650 M3 Checkpoint Code Display 9f

Don't forget to share! LEDs on the system board - To identify the component that is causing the Light path diagnostics LEDs The following table lists the LEDs on the light path diagnostics panel, the If the system-error LED is lit, it indicates that an error has occurred; go to step 2. Check the LEDs on the system board to identify the component that is causing the error.

  1. Make sure that the DIMMs are installed in the correct sequence (see Installing a DIMM for more information). (Trained service technician only) Replace the microprocessor that controls the failing DIMMs. (Trained
  2. Switch the bank back to the primary bank. (Trained service technician only) Replace the system board. 3818007 CRTM update capsule signature invalid Run the Setup utility, select Load Default Settings, and
  3. Remove all hardware that is not listed on the ServerProven website at the IBM ServerProven website.
  4. Error messages This section provides the list of error codes and messages for UEFI/POST, IMM, and DSA that are generated when a problem is detected.
  5. For more information, go to the "Before you call IBM Service" website.
  6. Press this button to force a nonmaskable interrupt to the microprocessor.

The following illustration shows the LEDs and connectors on the system board. Note: Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server. Replace any components that are identified in the error log. Ibm Light Path Diagnostics Checkpoint Codes Reseat the DIMMs.

The Reset button is in the lower right-hand corner of the light path diagnostics panel. Ibm Checkpoint Code 9f The remind function is controlled by the IMM. NMI A nonmaskable interrupt has occurred, or the NMI button was pressed. See Parts listing, IBM System x3550 M3 Type 4254 and 7944 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

See System-board switches and jumpers for the location of the SW4 switch block on the system board. Ibm Checkpoint Codes If the failure remains, go to the "Before you call IBM Service" website for additional troubleshooting information. Restart the server to see whether the problem remains. If the MEM LED and the CNFG LED are lit, complete the following step: Check the system-event log in the Setup utility or IMM error messages.

Ibm Checkpoint Code 9f

Follow steps indicated in POST error codes and Integrated management module error messages. Information only. Ibm X3650 M3 Checkpoint Code Display 9f Checkpoint code display: This display provides a checkpoint code that indicates the point at which the system stopped during the boot block and POST. Ibm Light Path Diagnostics Replace the hard disk drive backplane.

Clear CMOS memory to ensure that all DIMM connectors are enabled (see System-board switches and jumpers). http://domcached.com/checkpoint-code/ibm-error-code-9f.html PCI An error has occurred on a PCI bus or on the system board. The Reset button is in the lower-right corner of the light path diagnostics panel. Memory online-spare channel has been activated to back up a failed DIMM. Light Path Diagnostics Checkpoint Codes

Reseat the DIMMs and restart the server. Replace the failing DIMM. (Trained service technician only) Replace the system board. 0051006 DIMM mismatch detected Note: Each time you install or remove a DIMM, you must disconnect the server from Replace any failing device. (Trained service technician only) Replace the system board. check over here If the failure remains, go tothe "Before you call IBM Service" website for additional troubleshooting information.

Update the server firmware to the latest level (see Updating the firmware). (Trained service technician only) Replace the microprocessor. 0018010 Microprocessors of the same model have mismatched stepping ID. Ibm Light Path Diagnostics Dasd 9f If a system error has 2. Note: When you slide the light path diagnostics panel out of the server to check the LEDs or checkpoint codes, do not run the server continuously with light path diagnostics panel

Replace the following components one at a time, in the order shown, restarting the server each time: Battery (Trained service technician only) System board 3058001 System configuration invalid Run the Setup

Don't show me this message again. Make sure that the power supplies are seated correctly. When the server is in Remind mode, the system-error LED on the front of the server flashes. Ibm X3650 Dasd Error Light Solving power problems Use this information to solve power problems.

CNFG A hardware configuration error has occurred. Check the system-error log for information about the error. Check the system-event log in the Setup utility or IMM error messages. this content The light path diagnostics panel must remain in the server when the server is running to ensure proper cooling.

LOG An error occurred. Parent topic: Light path diagnostics panel Parent topic: Light path diagnostics Light path diagnostics panel The light path diagnostics panel is located on the top of the operator information panel. PS1 PS2 VRM CNFG NMI S ERR DASD RAID TEMP BRD Chapter 5. Note: When you slide the light path diagnostics panel out of the server to check the LEDs or checkpoint codes, do not run the server continuously with the light path diagnostics

Make sure that the virtual media key is seated and not damaged. (Trained service technician only) Replace the system board. 3808002 Error updating system configuration to IMM Shut down the system BRD An error has occurred on the system board. Memory redundancy has been lost. Certain components inside the server have LEDs that are lit to indicate the location of a problem.

If no memory fault is recorded in the logs and no DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the Advanced Settings Utility