Home > Checkpoint Code > Ibm X346 Error Light

Ibm X346 Error Light

Contents

LED Description Action None, but the system error LED is lit. Don't show me this message again. An error has occurred and cannot be isolated. Syed Jahanzaib Personal Blog to Share Knowledge ! http://domcached.com/checkpoint-code/ibm-pci-error-light.html

The error is not represented by a light path diagnostics LED. Hairy Gunt Ars Tribunus Militum Registered: Dec 8, 2008Posts: 1716 Posted: Thu Apr 01, 2010 12:38 am The reset button doesn't work during POST (the lightpath controller doesn't know the state what is this issue. Replace any failing device. (Trained service technician only) Replace the system board. (Continued on the next page) OVER SPEC (Continued) The power supplies are using more power than their maximum rating.

Ibm Light Path Diagnostics

but I tried to reput CPU again and after that i gor CPU LED lightining please advice Log in to reply. If you hit the remind button again, it should show you the last LED that was illuminated on the Light Path panel.Well, to the extent that I replaced the failed PS An additional LED is lit next to a failing PCI slot. Reinstall each device that you removed in step 2 one at a time, starting the server each time, to isolate the failing device.

  1. Display a chain of little mountains with an odd number on the top of it!
  2. There are no light diagnostics lit up and I cannot get to the POST error logs because the screen is blank and nothing displays because the beeps halt it.
  3. If you hit the remind button again, it should show you the last LED that was illuminated on the Light Path panel.
  4. Such problem has been fixed in BIOS 1.04 six years ago.
  5. Mohamed, read section "Light path diagnostics LEDs" for action plan details: Problem Determination and Service Guide - IBM eServer xSeries 346 http://www-947.ibm.com/systems/support/supportsite.wss/docdisplay?lndocid=MIGR-56806&brandind=5000008 Regards, Alexander Novikov Russia, Moscow Log in to reply.

This is the accepted answer. Howto do Power Recycling / Cold Restart # Shutdown the Server # Remove Power cables (both) from power supply. # Wait for 10 Minutes, # Now plugin the power cables and Generated Thu, 24 Nov 2016 17:11:33 GMT by s_mf18 (squid/3.5.20) Ibm X3650 M3 Checkpoint Code Display 9f Hi Mohamed, remove 2nd CPU and 2nd VRM, update server's software, place CPU and VRM back.

SystemAdmin 110000D4XK 9111 Posts Re: IBM X346 not working ‏2010-05-18T07:36:24Z This is the accepted answer. Light Path Diagnostics Checkpoint Codes When I hit the remind button, it illuminates the MEM on one box, and PS2 on the other...related to the original fault?lol @ both scorp and Zaphod. First of all you must update ALL server's software: Software and device drivers xSeries 346 http://www-947.ibm.com/systems/support/supportsite.wss/selectproduct?familyind=5178881&typeind=0&osind=0&brandind=5000008&taskind=2&matrix=Y&psid=sp&continue.x=15&continue.y=17 Regards, Alexander Novikov Russia, Moscow Log in to reply. https://www.ibm.com/developerworks/community/forums/thread.jspa?threadID=397590 Replace any components that are identified in the error log.

is there any more danger to fully power off vs reboot? (power to the raid, i dunno) Can we just live with this light? Ibm Checkpoint Codes I didn't want to do this from inside of a running OS (server 2k3 on one and ESX4 on the other), so I tried the reset from various points during POST, For more information, see the "Hard disk drive problems". When both the MEM and CNFG LEDs are lit, the memory configuration is invalid or the PCI Option ROM is out of resource.

Light Path Diagnostics Checkpoint Codes

The second part gives the meaning of the error. https://aacable.wordpress.com/2012/02/21/ibm-xseries-systemx3650-dasd-light-error/ Hi Alexander, I removed CPU2 and powered on the server but it didn't come up. Ibm Light Path Diagnostics Restart the server to see whether the problem remains. Ibm Checkpoint Code 9f Reinstall each device that you removed in step 2 one at a time, starting the server each time, to isolate the failing device.

Note: If an LED near an unused fan connector on the system board is lit, a PCI riser-card assembly might be absent. Could you tell me what server's software to be updated and how to get it and update. RAID Reserved. Table 1. Ibm Light Path Diagnostics Checkpoint Codes

If an action step is preceded by "(Trained service technician only)", that step must be performed only by a trained service technician. If the error remains, replace the following components one at a time, in the order listed, restarting the server after each: Replace the hard disk drive. hi, it's 2 CPUs, BIOS 1.02 I was Reinstalling Cisco operating system and after restarting i had this error. http://domcached.com/checkpoint-code/ibm-error-light-dasd.html TrackBack URI Leave a Reply Cancel reply Enter your comment here...

Novikov_Alexander 100000HTD5 ‏2010-05-17T14:18:27Z Hi Mohamed, remove 2nd CPU and 2nd VRM, update server's software, place CPU and VRM back. Ibm X3650 Dasd Error Light Remove the PCI riser card from PCI riser connector 2 and the microprocessor in socket 2. After restarting the server it stopped working and i get error code 199 processor mismatch system halted.

If the power supply has failed, call for service.

Register Login Posting Guidelines | Contact Moderators Ars Technica > Forums > Operating Systems & Software > The Server Room Jump to: Select a forum ------------------ Hardware & Tweaking Audio/Visual Dear Mohamed, what about VRM2? OVER The power supplies are using more SPEC power than their maximum rating. Ibm Light Path Diagnostics Dasd 9f Glad to help you.

mohamedsherif 2700036J8Q ‏2010-05-16T16:06:12Z Hi Alexander, sorry but I'm new in IBM world. Like all the other codes out there. I keed I keed! this content Get 1:1 Help Now Advertise Here Enjoyed your answer?

This is the accepted answer. This is the accepted answer. Replace any failing device. (Trained service technician only) Replace the system board. (Continued on the next page.) OVER SPEC (Continued) The power supplies are using more power than their maximum rating. The little exclamation point light on the front is on.

They can have an army of blue suits there next week to tell your CEO all about it. Replace any components that are identified in the error logs. First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. And, yes, people still use them and some refuse to give them up.

Lo and behold, your blog is useful to me once again! Restart. mohamedsherif 2700036J8Q ‏2010-05-16T09:44:22Z hi, it's 2 CPUs, BIOS 1.02 I was Reinstalling Cisco operating system and after restarting i had this error. The BRD LED can be lit due to any of the following reasons: Battery Missing PCI riser-card assembly Failed voltage regulator Check the system-error log for information about the error.

More... server model: Xseries-346 - 8840-3RY what can I do? CNFG A hardware configuration error has occurred. Remove the optical drive, fans, hard disk drives, and hard disk drive backplane.

Thus 200 means the system memory was tested. And if you happen to disagree with their business case it only shows that you aren't kind of forward thinking employee who should be in the decision making loop. I keed I keed!